• Fibershield®-P

Ideal for efficient fire protection of large dimensions: The textile fire protection curtain Fibershield-P is approved for widths up to 10 m and drop lengths of up to 7.6 m. Larger dimensions are technically feasible. Different classifications can be achieved flexibly by using different types of fabric. The curtain can be moved with just one drive system. As standard, Fibershield-P is equipped with the tried and tested "Gravigen" drive, which closes without requiring an external power source. With numerous design variants, Fibershield-P offers plenty of scope for customer-specific solutions.

  1. Smoke detector
  2. Casing
  3. Side guide
  4. Fixing bracket
  5. Fabric
  6. Closing element
  7. Tubular motor
  8. Control module
  9. Control with operating unit
  10. Manual release



  • Fibershield®-E

High degree of standardisation and thus economical shielding system with "Gravigen" drive system, i.e. closing without external energy, so that no fire-resistant cables are required.

10.000 motor cycles are possible. Different classifications achievable through different fabric types. Large fire protection curtain systems at least class C 2.

Equipment options: Safety contact strip, spring-loaded closing strip

  1. Smoke detector
  2. Casing
  3. Side guide
  4. Fixing bracket
  5. Fabric
  6. Closing element
  7. Tubular motor
  8. Control module
  9. Control with operating unit
  10. Manual release



  • Fibershield®-I

In case of alarm self-closing, thermally insulating fire protection closure of textile construction in vertical installation position and closing direction.

  1. Smoke detector
  2. Housing
  3. Guide rails
  4. Attachment bracket
  5. Fabric
  6. Closing element
  7. Tubular motor
  8. Control module
  9. Control with operating unit
  10. Manual release



  • Fibershield®-H

The textile horizontal fire protection curtain for ceiling openings
Even large ceiling openings that required a wide area closure with extensive drop length can be optimally protected against the effects of fire with the Fibershield-H fire protection curtain. The system is characterised by its versatile mounting possibilities (below the ceiling, in the embrasure) and by its construction design. In the event of alarm, the system reliably closes by means of spring force without requiring an external power source.

  1. Smoke detector
  2. Casing
  3. Side guide
  4. Fabric
  5. Closing element
  6. Tubular motor
  7. Control module
  8. Control with operating unit
  9. Manual release



  • Fibershield®-HC

The new generation of horizontal textile fire protection curtains - without supporting and tensioning cables! Fibershield-HC was specially developed as a closure system for large ceiling openings up to 10 x 10 m. The curtain with the additionally reinforced Heliotex EW 120 is positioned in a space-saving casing, which forms a closed unit together with the closure rail. A two-piece version sized 10 x 20 m with centrally locking end rails is being planned. This system is able to easily close large openings in ceilings.

  1. Smoke detector
  2. Casing
  3. Sideguide
  4. Fabric
  5. Closing element
  6. Tubular motor
  7. Control module
  8. Control with operating unit
  9. Manual release



  • Fibershield®-S

Fire protection that leads around corners: The floor space of the closure can be realised in a rectangular and polygon-shape with angles between 30° and 150°. No support elements are required despite the corner design. In addition to a closed polygon shape, open systems can also be realised that close against the wall by installing special guide rails. A spring-loaded closing strip presses tightly against the ceiling and provides a proper closure. The fire protection curtain can be closed without any external energy by means of the 'Gravigen' drive system that is included as standard. The Fibershield-S complex allows for complex sealing geometries to be realised, while also complying with the requirement of closing off a space for more than 90 minutes.

  1. Smoke detector
  2. Casing
  3. Side guids
  4. Tubular motor
  5. Fabric
  6. Closing element
  7. Coil
  8. Control module
  9. Control with operating unit
  10. Manual release